概要 |
AX8525和AX8540组合电源和轴模块将AX86xx电源模块和AX81xx轴模块的功能统一在一个设备上。因此,AX-Bridge不受第一个轴的轴电流负载,并且可为其他轴模块提供高达50 a的直流电。电源向直流链路提供80a直流,并包含一个内部制动电阻以及用于连接外部制动电阻的斩波器。具有TwinSAFE安全功能的集成轴模块可提供额定电流为25 a或40 a,并可选择订购多反馈接口。
调测工具为TwinCAT 3 Drive Manager 2。由于结构设计和广泛的功能,轴的调试简单直观。 |
技术数据 |
Product variants |
Number of channels |
Rated output current (channel) |
Peak output current (channel) |
TwinSAFE safe drive technology |
Feedback system |
Supported types of motors |
AX8540-0100-0000 |
1 |
40 A |
80 A |
STO/SS1 |
OCT, EnDat 3 |
synchronous servomotor | asynchronous motor |
AX8540-0120-0000 |
1 |
40 A |
80 A |
STO/SS1 |
OCT, EnDat 3, BiSS C, EnDat 2.2/22, TTL (DIFF RS422), SinCos 1 Vpp |
synchronous servomotor | linear motor | asynchronous motor |
AX8540-0200-0000 |
1 |
40 A |
80 A |
Safe Motion |
OCT, EnDat 3 |
synchronous servomotor | asynchronous motor |
AX8540-0220-0000 |
1 |
40 A |
80 A |
Safe Motion |
OCT, EnDat 3, BiSS C, EnDat 2.2/22, TTL (DIFF RS422), SinCos 1 Vpp |
synchronous servomotor | linear motor | asynchronous motor |
|
Technical data |
AX8540-0100-0000 |
Function |
combined power supply and axis module with TwinSAFE Logic |
Channels |
1 |
Rated supply voltage |
3 x 200…480 V AC |
DC link voltage |
max. 848 V DC |
DC link output current |
80 A DC |
Rated output current (channel) |
40 A |
Peak output current (channel) |
80 A |
Feedback |
OCT , EnDat 3 |
System bus |
EtherCAT |
Drive profile |
CiA402 according to IEC 61800-7-201 (CoE) |
Realization STO |
by local TwinSAFE Logic, via FSoE or hard-wired via safe inputs |
Safe stop functions |
Safe Torque Off (STO), Safe Stop 1 (SS1) |
Safety standard |
EN ISO 13849-1:2015 (Cat 4, PL e), EN 61508:2010 (SIL 3) and EN 62061:2005 + A1:2013/A2:2015 (SIL CL3) |
Ambient temperature (operation) |
0…+40°C, up to +55°C with power reduction (see documentation) |
Approvals/markings |
CE, cULus, EAC |
|
echnical data |
AX8540-0120-0000 |
Function |
combined power supply and axis module with TwinSAFE Logic and multi-feedback interface |
Channels |
1 |
Rated supply voltage |
3 x 200…480 V AC |
DC link voltage |
max. 848 V DC |
DC link output current |
80 A DC |
Rated output current (channel) |
40 A |
Peak output current (channel) |
80 A |
Feedback |
OCT , EnDat 3 , BiSS C , EnDat 2.2/22 , TTL (DIFF RS422) , SinCos 1 Vpp |
System bus |
EtherCAT |
Drive profile |
CiA402 according to IEC 61800-7-201 (CoE) |
Realization STO |
by local TwinSAFE Logic, via FSoE or hard-wired via safe inputs |
Safety standard |
EN ISO 13849-1:2015 (Cat 4, PL e), EN 61508:2010 (SIL 3) and EN 62061:2005 + A1:2013/A2:2015 (SIL CL3) |
Ambient temperature (operation) |
0…+40°C, up to +55°C with power reduction (see documentation) |
Approvals/markings |
CE, cULus, EAC |
|
Technical data |
AX8540-0200-0000 |
Function |
combined power supply and axis module with TwinSAFE Logic |
Channels |
1 |
Rated supply voltage |
3 x 200…480 V AC |
DC link voltage |
max. 848 V DC |
DC link output current |
80 A DC |
Rated output current (channel) |
40 A |
Peak output current (channel) |
80 A |
Feedback |
OCT , EnDat 3 |
System bus |
EtherCAT |
Drive profile |
CiA402 according to IEC 61800-7-201 (CoE) |
Realization STO |
by local TwinSAFE Logic, via FSoE or hard-wired via safe inputs |
Safe stop functions |
Safe Torque Off (STO), Safe Operating Stop (SOS), Safe Stop 1 (SS1), Safe Stop 2 (SS2) |
Safe acceleration functions |
Safe Maximum Acceleration (SMA), Safe Acceleration Range (SAR) |
Safe braking functions |
Safe Brake Control (SBC), Safe Brake Test (SBT) |
Safe direction functions |
Safe Direction positive (SDIp), Safe Direction negative (SDIn) |
Safe speed functions |
Safely Limited Speed (SLS), Safe Speed Range (SSR), Safe Speed Monitor (SSM), Safe Maximum Speed (SMS) |
Safe position functions |
Safely Limited Position (SLP), Safe CAM (SCA), Safely Limited Increment (SLI) |
Safety standard |
EN ISO 13849-1:2015 (Cat 4, PL e), EN 61508:2010 (SIL 3) and EN 62061:2005 + A1:2013/A2:2015 (SIL CL3) |
Ambient temperature (operation) |
0…+40°C, up to +55°C with power reduction (see documentation) |
Approvals/markings |
CE, cULus, EAC |
|
Technical data |
AX8540-0220-0000 |
Function |
combined power supply and axis module with TwinSAFE Logic and multi-feedback interface |
Channels |
1 |
Rated supply voltage |
3 x 200…480 V AC |
DC link voltage |
max. 848 V DC |
DC link output current |
80 A DC |
Rated output current (channel) |
40 A |
Peak output current (channel) |
80 A |
Feedback |
OCT , EnDat 3 , BiSS C , EnDat 2.2/22 , TTL (DIFF RS422) , SinCos 1 Vpp |
System bus |
EtherCAT |
Drive profile |
CiA402 according to IEC 61800-7-201 (CoE) |
Realization STO |
by local TwinSAFE Logic, via FSoE or hard-wired via safe inputs |
Safe stop functions |
Safe Torque Off (STO), Safe Operating Stop (SOS), Safe Stop 1 (SS1), Safe Stop 2 (SS2) |
Safe acceleration functions |
Safe Maximum Acceleration (SMA), Safe Acceleration Range (SAR) |
Safe braking functions |
Safe Brake Control (SBC), Safe Brake Test (SBT) |
Safe direction functions |
Safe Direction positive (SDIp), Safe Direction negative (SDIn) |
Safe speed functions |
Safely Limited Speed (SLS), Safe Speed Range (SSR), Safe Speed Monitor (SSM), Safe Maximum Speed (SMS) |
Safe position functions |
Safely Limited Position (SLP), Safe CAM (SCA), Safely Limited Increment (SLI) |
Safety standard |
EN ISO 13849-1:2015 (Cat 4, PL e), EN 61508:2010 (SIL 3) and EN 62061:2005 + A1:2013/A2:2015 (SIL CL3) |
Ambient temperature (operation) |
0…+40°C, up to +55°C with power reduction (see documentation) |
Approvals/markings |
CE, cULus, EAC |
|
|
|
|
|
|
|
产品样本 |
|
|
|
|
|
|
|
|
|
|
|
|
|