Workpiece touch probe |
Cable |
TS260 |
TS150 |
TS750 |
Probe accuracy |
≤±5μm with use of the T404
standard stylus (at a probing
speed of 1000mm/min) |
≤±5μm with use of the T434
standard stylus (at a probing
speed of 500mm/min) |
Probe repeatability
Repeated probing from
one direction |
2α≤1μm
Typical values: 2α≤0.5μm |
2α≤0.25μm |
Probing force |
Axial:≈7N
Radial:≈1N |
Axial:≈15N
Radial:≈0.2N |
Deflection of probe
contact |
≤5mm in all directions (with stylus length L=40mm) |
Deflection forces |
Axial:≈8N
Radial:≈1N |
Probing speed
(recommended) |
≤3m/min |
≤1m/min |
Protection EN 60529 |
IP68 |
Operating temperature |
10°C to 40°C |
5°C to 54°C |
Storage temperature |
-20°C to 70°C |
Mass without taper shank |
≈0.15kg |
≈0.1kg |
Fastening* |
With taper shank (only with
radial flange socket)
Via M28x0.75 external thread
Via coupling joint with M22x1
external thread |
Base with M22x1 thread and axial cable outlet
Base with three M3 screws and axial cable outlet
Base with four M3 screws and axial cable outlet
Optional: touch-probe extension with M16x1 thread |
Electrical connection |
8-pin M12 flange socket, axial or
radial |
Two-pole sliding contact on the mounting base |
Cable length |
≤25m |
Power supply |
DC 10V to 30V/? 100mA
(without load) |
DC 10V to 30V/? 85mA (without load) |
Output signals |
Trigger signals S and S (square-wave signal and its inverted signal)
Floating trigger output |
HTL signal levels |
UH≥20V at –IH≤20 mA
UL≤2.8V at IL≤20 mA
at rated voltage of DC 24V |
Signal transmission |
Cable |